How To Clean The Fiber Optic Connector ?

Fiber optic cleaning is one of the most important thing in the process of fiber optic system maintenance, which is required to keep quality connections between fiber optic equipment. As we know, the fiber optic connector consists of fiber optic plug and the adapter. The ends of the fiber optic cables are held in the core of ferrule in the plug. Keeping the fiber end face and ferrule absolutely clean is very essential, since any particles such as dust, oil or lint on the end face of the fiber, it will disrupt the light transmission trough the fiber and lead to the completeness of optical signals for the component or the entire system.
For proper performance of the SC fiber optic cable, you must keep the SC connector clean and free of dust. Small micro-deposit of oil and dust in the canal of the connector could cause loss of light, reducing signal power and possible causing intermittent problems with the optical connections. Below picture show the part of the end face of an unclean and clean ferrule of SC connectors.
What should be followed before the fiber optic cleaning
1.Before cleaning the fiber optic connectors, make sure to disconnect the fiber optic cables from both ends and then turn off any laser source.
2. Do not allow the end of the fiber optic cable to make contact with any surface including your fingers.
3.Never to bend the fiber cable, which will in turn cause internal breaks along the fiber and cause poor performance or instability.
4.Use the finger cots or powder free surgical gloves to handle the fiber optic cables.
5.Use fresh spectroscopic grade Methanol or Isopropyl Alcohol as the only cleaning solvent.
6. In the daily connection work, a connector housing should be used when plugging or unplugging a fiber. A protective cap should be used to cover the unplugged fiber connectors.
7. In the process of the fiber optic cleaning, the end face of the connector should never be touched and also the clean area of a tissue of swab should not be touched or reused.
Cleaning Procedure
At the beginning of cleaning job, a fiber microscope should be used to inspect the fiber end, if it is contaminated as either images shows below, it should be cleaned with the dry cleaning method.
1.Blow the fiber surface with a stream of Clean Dry Air (the so called CDA), which will dislodge larger, loose particles. Keep in mind, don’t tip the can of the CDA while blowing. Because the liquid may be released contaminant on the surface of the fiber.
2.Place 1-3 drops of spectroscopic grade methanol or isopropyl alcohol in the center of a lens tissue. Do not use Acetone as a cleaning solvent on the fiber optical surfaces. Besides, to ensure the purity of the methanol or alcohol, you should never insert the lens tissue or swabs into the liguid.
3.Hold the fiber by the connector. Place the wet portion of the lens tissue on the optical surface and slowly drag it across. At this step, don’t use lens paper to dry it because the dry lens paper is extremely abrasive.
4.Examine the surface of the fiber under high density light using a magnifier, an optical loop, or a video inspection tool. If streaks or contaminants still remain, repeat the process using a fresh lens tissue.
5.Immediately install a protective cover over the end of the cable to avoid re-contamination or insert the fiber for immediate use.

Thursday, November 27, 2014

the world's top supplier of fiber optic products

FiberYes.com is the world's top 10 in the optical fiber communication products online store. On FiberYes.com, you can find all 10Gtek Transceivers Co., LTD factory direct DAC cables including 10GBASE Cables such as SFP+ DAC, XFP Infiniband, MiniSAS (SFF-8088) and CX4 (SFF-8470), and 40GBASE-CR4/SR4 QSFP+ and QSFP+ to SFP+ (4) breakout. All of these products have passed CE, ROHS, etc., and 100% tested.

Why choose FiberYes.com?
1.Best Quality --- First-class production technology & skills with top-clean anti-static workshop and advanced production equipment, together with severe reliability test & quality control speak for our best quality.
2.Lowest Price --- Mass procurement and mass production ensures low purchase cost; improving first pass yield (FPY) and reliability decrease after-sale cost; customized product design gives our products the privilege of low cost and strong competitiveness.
3.Fast Delivery --- Over USD500,000 regular products in stock. Same-day shipping is very common. Shipments are delivered by DHL, FedEx and UPS, etc,. Fast, safe and trackable on-line.
4.Good Compatibility and Stability --- All our products have gone through strict compatibility tests on the prevalent brands of switching devices and router devices. This secures the products' compatibility and stability on your devices.
5.Buy Risk-Free --- Your purchases from FiberYes.com are always risk-free. Contact us if you are not satisfied with your purchase for any reason. We will refund you for items sending back within 7 days after you get them. A full refund will be given if items are returned in their original condition.
6.Privacy --- At FiberYes.com, we understand and respect your concern about the privacy of any information you provide at our site. Any information collected from you are protected from betrayal to any third parties and is for order-fulfillment purpose only.

What does FiberYes.com offer?
FiberYes.com offers DAC Twinax Cables, optical transceivers and adapters for your datacom, telecom and networking solutions:
*10GBASE SFP+ DAC, Passive & Active Cable and Module
*40GBASE QSFP+, Cable and Module
*10GBASE XFP Infiniband Cable and Module
*Internal MiniSAS (SFF-8088) Cable and Module
*CX4 Infiniband (SFF-8470) Cable and Module
10G Transceiver Series: SFP+, XFP, XENPAK, X2
SFP Transceiver Series:100M, 1.25G, BIDI, CWDM, DWDM
SDH Transceiver Series:OC3, OC12, OC48, BIDI, CWDM, DWDM
Optical Patch Cords:OM1, OM2, OM3, OS1
10GB CNA/ NIC/ HBA

Who is 10Gtek?
10Gtek Transceivers Co., LTD is a professional manufacturer specialized in R&D, production, sales and services of DAC Twinax Cable assembly and Optical Transceiver products include DAC twinax cables (SFP+ Cables, QSFP+ Cables, XFP Cables, Mini SAS Cables, CX4 Cables, Infiniband Cables, QSFP+ AOC cables... ) Optical Transceivers (SFP, SFP+, XFP, X2, XENPAK, SDH, Bidi ), OADM/MUX/Demux, Fiber Optic Patch Cords, Fiber Optic Components, etc. The main application fields are transmission network, data network, access network and passive optical network (PON) of metropolitan area network, etc.
10GTEK's DAC twinax cable assemblies are available in lengths up to 15m (50ft) to meet your network, data center, or HPC installation requirements. All 10Gtek's cables have passed Rohs, CE. Plus, 10Gtek's DAC twinax Cables will cross reference with ANY competing brand copper Cable.
Relying on its sharp market insight, strong R&D capabilities and continuous efforts, now 10Gtek has become one of the earliest suppliers for 40G QSFP+ series. Presently, the company products cover all series of different optical transceivers and DAC twinax high performance (speed) cables.
10Gtek adheres to the business philosophy of "Technology Innovation, Quality First, Continuous Improvement, Integrity and Pragmatic". Keeping improving quality, reducing costs, shortening delivery time and enhancing manufacturing flexibility is 10Gtek's constent pursuit.
10Gtek is committed to being a reliable partner in optical communication and high speed data processing industry, dedicated to providing customers with satisfactory services.
Company Goals: To be a strategic supplier in optical networking industry.
Business Philosophy: Technology Innovation, Quality First, Continuous Improvement, Integrity and Pragmatic.
Company Policy: Market leads development, Technology creates products, System makes quality, Service satisfies customers.
Company Tenet: Customer Satisfaction, People-Oriented.
10Gtek brings together a number of experts and engineers who have rich experience in developing optoelectronic products to provide high quality products for the rapid-growing optical communication industry. It aims to respond quickly to customer needs, to provide customers with good compatibility, competitive products and customization and design services.

Friday, November 21, 2014

Do You Really Know SFP-OC48-LR2? Fiberyes

As we all know, SFP-OC48-LR2 is a type of Cisco SFP modules. But do you really know the meaning of the words in the SFP-OC48-LR2? I think the “SFP” and “LR2″ are known as SFP modules with 80km transfer distance by most people, while the “OC48″ is not understood by them including myself before today. And after searching on the internet, I write this article to talk about it.

In fact, many network engineers and IT managers are not up to speed on just what OC really means, although they have used the 2.5G SFP 80km or 1550 SFP 80km. And what all is available to enahnce their company’s applications within this bandwidth category. The first that we should know is, the OC is short for Optical Carrier (fiber optic based broadband network) with speed hierarchy starting with OC1 on optical facilities and going as follows.
OC1 = 51.840Mbps (the basic rate)
OC3 (3 times of OC1) = 155.52Mbps (about 155Mbps)
OC9 (9 times of OC1) = 466.56Mbps (not commonly used)
OC12 (12 times of OC1) = 622.08Mbps (about 622Mbps)
OC18 (18 times of OC1) = 933.12Mbps (not commonly used)
OC24 (24 times of OC1) = 1.244Gbps (not commonly used)
OC36 (36 times of OC1) = 1.866Gbps (not commonly used)
OC48 (48 times of OC-1s) = 2.488Gbps (about 2.5Gbps)
OC192 (192 times of OC1s) = 9.953Gbps (about 10Gbps)
OC48 is among the most used bandwidth that has applications including large enterprise or ISP backbone. Let’s discuss its specific advantages.
The utilisation of the internet by consumers and businesses is definitely an incredible market through which optical carriers are starting to supply the most leading edge appeal. With this particular facet of the internet world in your mind, any business or perhaps consumer should consider the incredible advantages offered in the OC48.
OC48 is used by larger businesses and corporations because they allow for an incredibly fast and dependable source of internet. They are currently equipped to handle probably the most amounts of data in the industry as well as offer the fastest speeds. As such, businesses that current operate on a much grander scale and would like to keep growing are the ones that help the most from this technique.
Within the optical carrier realm of data connection, there are quite a few ranges of speed and capability which are numerically labeled. The OC48 is really the mid-range source of data which allows to have an incredible fast rate of internet connection overall. It is probably the most popular carriers to replace T-Carrier lines. The T carriers of web connection for businesses was discovered and implemented in the 1960s for people who needed the fastest and more reliable data sources on the market for that time. This form of internet sourcing actually led the way for intranets and broad area networks that kept businesses connected all the time.
OC48 is really within the mid range of connection and strength. This range is complete with a processing capacity for 2.5Gbps which is actually quite robust. This really is perfect in strength for just about any larger business to expand within too. This optical carrier system could be quite expensive to establish for just about any business that often ranges in beginning costs of 30 to 40 thousand dollars. The monthly rates are quite steep as well yet many companies feel the costs are justified. As such, this is often from range for smaller to medium-sized businesses.

In order to operate an OC48 connection, there must be an amazing strong telecommunications source operating it. Some of the more reputable isps are beginning to come on line with this particular strength of the system. This, in turn, makes it more readily available for those that wish to use it.

Thursday, September 11, 2014

How To Choose A Fiber Transceiver

How To Choose A Fiber Transceiver


Fiber transceiver used in the Ethernet cable cann't be overwritten, you must use the fiber to extend transmission distance of the actual network environment, help fiber last-km line to connect to the metro and the outer layer of the network playa huge role. With fiber optic transceivers, also need to upgrade from copper to fiber optic, but lack of funds, manpower or time the user provides an inexpensive program.

In order to ensure fully compatible with the NICs, repeaters, hubs and switches and other network equipment of other manufacturers, fiber optic transceiver products must strictly comply with 10Base-T, 100Base-TX, 100Base-FX, IEEE802.3 and IEEE802.3u Ethernet standard. In addition, EMC anti-electromagnetic radiation shall comply with FCC Part15. Nowadays, the major domestic carriers are great efforts to build the residential network, campus and enterprise networks, so the amount of fiber-optic transceiver products are constantly improved to better meet the access network construction needs.

How to choose a fiber transceiver? Due to fiber converter is one of the LAN connection device, it is necessary to consider the mutual compatibility with the surrounding environment, and product stability, reliability, and vice versa: the prices were lower, cann't get customer all like!

1. Whether to support full-duplex and half duplex?

Some chips on the market currently only use full-duplex environment, can not support half-duplex, such as the receipt of other brands of switches or HUB and it is using half-duplex mode, will cause serious conflict and loss.

2. Whether and other optical transceiver done connection test?

An increasing number of currently available fiber optic transceivers, transceivers, such as the mutual compatibility of different brands of transceivers in advance didn't make the test will produce loss, the transfer time is too long, suddenly fast and slow phenomena such as.

3. Whether there is a safety device to prevent packet loss?

Some vendors in the manufacture of fiber optic transceivers, transceiver, in order to reduce costs, often the data transfer mode register, this approach is the biggest drawback is instability in the transmission, packet loss, and the best is to use the buffer line. can be safe and to avoid data loss.

4. Temperature adaptability?

Fiber optic transceivers, when used, will produce high fever, high temperature (not greater than 85C), fiber optic transceiver is working properly? Is very worthy of the factors that customers consider!

5. Whether conforming to the IEEE802.3u standard?

Such as fiber optic transceivers comply with IEEE802.3 standard, that the delay time control in 46bit, it means that the transmission distance of fiber-optic transceiver will be shortened if more than 46bit!







Wednesday, September 3, 2014

SAS (SFF-8470) to (4) SATA Cable

SAS (SFF-8470) to (4) SATA Cable 1M


SAS (SFF-8470) to (4) SATA Cable 1M


SAS technology guarantees performance at 3.0 Gigabits per second. This 4x SAS cable features SAS type SFF-8470 thumbscrew connectors and External SATA connectors. SAS to SATA breakout crossover cables connect a SFF-8470 SAS Controller directly to 4 SATA drives.

Specifications:
●Length = 1M
●Wire Size (AWG) = 28
●Connector A = SFF-8470 (Thumbscrews)
●Connector B = (4) SATA (SATA )
●Crossover Wiring
●Impedance = 100 Ohms
●High performance 8 pair wire construction
●Exceeds SAS 1.1 and SATA 2 Specification
●Due to the popularity of Mini SAS products, please call to confirm availability.

Source: 10Gtek optic cable

Tuesday, August 26, 2014

10GbE XFP to XFP Copper Cable

10GbE XFP to XFP Copper Cable 1M, Passive


XFP Infiband Cables were developed to provide 10Gb/s serial links for a wide range of applications including standards such as OC192/STM-64, G.709, and 10 Gigabit Ethernet, 10G Fibre Channel, and other industry standards. It is ideally suited for 10 GbE datacom (belly-to-belly for high density applications) and storage area network (SAN/NAS) applications based on the IEEE 802.3ae and Fiber Channel standards.

Fiberyes.com's XFP to XFP Cable is a low cost XFP-SR Optical transceiver replacement solution, which have equal performance with XFP SR transceivers. This XFP directly attached twinax cable assemblies are suitable for very short distances (0.5m to 15m) and offer a highly cost-effective way to connect within racks and across adjacent racks. Transmitter and receiver are separate within a wide temperature range and offers optimum heat dissipation and excellent electromagnetic shielding thus enabling high port densities. This XFP direct-attached twinax cable assembly is Fiberyes' innovatively designed cable, which is controlled by the MCU on the extraction of A0 and A0H adress bit to meet the requirements of the XFP MSA.


10GbE XFP to XFP Copper Cable 1M, Passive
10GbE XFP to XFP Copper Cable

Product Features:
● XFP to XFP Connetor
● Copper Passive
● 1 Meter
● AWG24
● Compliant to XFP MSA
● Compliance to Fiber Channel
1200-M5-SN-l, 1200-M5E-SN-l,
1200-M6-SN-l at 10.51875Gbit/s
● Low power consumption
● Wide operating temperature range:
Standard: 0°C to +70°C
Industrial: -40°C to +85°C
● Hot pluggable
● Lead free
● AC coupling of PECL signals
● Excellent EMI performance
● High reliability
● RoHS Compliant

Applications
● Data networking
● Telecommunications switches (SONET)
● Enterprise storage area network(SAN/NAS)
● Network switches and routers
● 10 GbE datacom (belly-to-belly for high density applications)

Source: www.fiberyes.com

Friday, August 22, 2014

BiDi SFP+ 10GBase-LR Tx1330/Rx1270nm 20KM

BiDi SFP+ 10GBase-LR Tx1330/Rx1270nm 20KM

BiDi SFP+ 10GBase-LR Tx1330/Rx1270nm 20KM
BiDi SFP+ 10GBase-LR Tx1330/Rx1270nm 20KM

BIDI SFP+ transceivers are designed for bi-directional 10GbE optical data communications such as IEEE 802.3ae 10GBASE-BX by using 1330(1270nm) transmitter and 1270(1330) nm receiver. The transceiver consists of two sections: The transmitter section uses a multiple quantum well 1330(1270) nm DFB laser and is a class 1 laser compliant according to International Safety Standard IEC 60825. The receiver section uses an integrated 1270(1330) nm detector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC.

Fiberyes.com offers BIDI SFP+ transceivers which reach distances from 10km up to 80km .

Product Description:

● Operating data rate up to 10.3Gbps
● 1330nm DFB Transmitter / 1270nm Receiver
● Distance up to 20km over SMF
● Single 3.3V Power supply and TTL Logic Interface
● LC Connector Interface,Hot Pluggable
● Compliant with SFP+ MSA Specification SFF-8431
● Compliant with IEEE 802.3ae 10GBASE-LR
● Compliant with IEEE 802.3ae 10GBASE-LW
● Compliant with SFF-8472
● Operating Case Temperature Standard:0℃ to +70℃


Application:


● 10GBASE-LR at 10.3125Gbps
● 10GBASE-LW at 9.953Gbps
● Other Optical Links

Source: www.fiberyes.com

Tuesday, August 12, 2014

10Gtek SFP+ DAC Twinax Cable 1m, AWG30, Passive


10Gtek SFP+ DAC Twinax Cable 1m, AWG30, Passive

SFP+ Copper Twinax cables are suitable for very short distances and offer a highly cost-effective way to connect within racks and across adjacent racks. SFP+ cables offers a low cost SFP+ solution. SFP+ directly attached twinax cable assemblies supports 10 Gigabit Ethernet, 10 Fibre Channel, and other industry standards.

10Gtek SFP+ DAC Twinax Cable 1m, AWG30, Passive

10Gtek SFP+ DAC Twinax Cable 1m, AWG30, Passive

Specifications:
● SFP+ to SFP+ Connetor
● Copper Passive
● 1 Meter
● AWG24/AWG30
● Compliant to SFP MSA 
● Low power consumption 
● Excellent EMI performance 
● High reliability
● RoHS Compliant 
● Wide operating temperature range:
Standard: 0℃ to +70℃
Industrial: -40℃ to +85℃

Applications:
● 1-8G Fiber Channel and 1-10G Gigabit Ethernet
● Networking, Storage, Telecommunications
● Hub, Switches, Routers, Servers, Network Interface Card(NICs)

Notice:
1. SFP+ Cables can meet compatibility* with Cisco System (Reference "Cisco Compatiblility Metrix").
2. SFP+ Cables can meet compatibility* with HP-Procurve Systems. Please choose by clicking "Compatible List".
3. SFP+ Cables can meet compatibility* with H3C/3COM Systems. Please choose by clicking "Compatible List". H3C/3COM Systems do not support active cables.
4. SFP+ Cables can meet compatibility* with Intel Systems. For Intel Card, Passive SFP+ cable should be within 3 meters ( 3m included) with AWG24. Longer than 3m distrance, you could choose our Active SFP+ cable. 
5. SFP+ Cables can meet compatibility* with Brocade Systems. Different Brocade systems may require different coding. Please enter your Brocade system model in the Remark box when ordering.
6. SFP+ Cables can meet compatibility* with Huawei/A-lu/D-link/Extreme/Foundry/Netgearg/Dell/IBM/... Systems. Please choose by clicking "Compatible List".

"Meet Compatibility*" means, WORKING with systems, without link or identification problems. 
Please note: 
To "meet Compatibility*" with system, we need to modify the eeprom infomation, wtihout short notice. The information include but not limited to "P/N", "Length", "Vender", etc
e.g.
The modification items:
a. To ensure the product compatibility with Cisco System, our SFP+ passive cables with cable lengths of 2 meters, 3 meters, and 10 meters may be coded as SFP-H10GB-CU1M 
b. To ensure the product compatibility with Cisco System, SFP-H10GB-ACU7M may be coded as SFP-H10GB-CU1M
c. To ensure the product compatibility with Cisco System, SFP-H10GB-CU1M may be coded as SFP-SR

For more information please visit

10Gtek optic cable


Sunday, April 13, 2014

SFP+ Transceivers significantly reduce power consumption

EX Series switches support SFP+ passive direct attach cables. The passive Twinax cable is a straight cable with no active electronic components. EX Series switches support 1 m, 3 m, 5 m, and 7 m long SFP+ passive direct attach cables.Small form-factor pluggable plus transceiver (SFP+) direct attach copper cables, also known as Twinax cables, are suitable for in-rack connections between servers and switches. They are suitable for short distances of up to 23 ft (7 m), making them ideal for highly cost-effective networking connectivity within a rack and between adjacent racks.If using SFP+ Transceivers assemblies between equipment that should be open, and the link is not working, a quick check can be performed by plugging in a different SFP+ cable assembly between the same two ports. If the link does come up, it is likely a problem with the first SFP+ cable assembly. If the link does not come up, it is likely a problem with the configuration of the ports or incompatibility between server and switch.There are some instances when passive SFP+ cables assemblies will not work, where the ports require an DWDM Transceiver assembly. Known CNA cards that require active SFP+ Transceivers assemblies include: Brocade (1010/1020 CNA) and QLogic (QLE-8xxx-SR CNA). The EMC VNX Series Unified Storage Systems also QSFP-4SFP1​0G-CU1M – Compatible Cisco QSFP+/4SFP​+ Copper Cable Breakout, 1 Meter
requires active SFP+ cable assemblies.

Tuesday, April 8, 2014

SFP+ Transceivers a product of our industry leading chip technology

, Apresia, Delta, F5 Netwoks, Finisar, Fortinet, Fujits, IBM, IMC Networks , Palo Lato Netwoks, Sun, Transition Networks, etc.SFP+ direct attached twinax cable assemblies are designed for use in 10-Gigabit Ethernet and 10-Gigabit Fibre Channel applications. These SFP+ Transceivers to meet their common objectives of broad bandwidth, small physical size and mass, and ease of removal and replacement. cables are Direct Att Compatible Cisco 40GBASE QSFP+ AOC Active Optical Cable, 15 Meters ached compliant and compliant with SFP+ MSA specification. Using Linux ethtool I can set the server to run the interface at 1Gb (ethtool -s eth0 speed 1000) but without luck. We're using a SFP+ cable which I believe is backward compatible with SFP.